Quality Policy

Quality

Bureau Veritas certify that the Manager System of Sanara Resistencias Eléctricas S.A. has been audited and found to be in accordance with the requirements of the management systems standards ISO9001:2008.

Certificado ISO9001 Sanara Resistencias Electricas, S.A.

List of aplicable standards:

Sanara Resistencias Eléctricas S.A. declares the conformity of its electrical heaters base on Directive 73/23 CEE of electrical products and harmonized standard UNE-EN-60335-1

NOTE: Due that the standard EN 60335 relates to apparatus and Sanara manufactures a product that should be incorporated into this apparatus, can not guarantee Sanara all the standard points. So Sanara declares conformity CE base on chapters 10, 13, 16 y 23 of that standard. The remaining required assurances, connections, abnormal operation, access to the active parts, protective earth Class I devices, etc. should be checked once the element has been incorporated into the device, as it depends on the final location.

Chapter 10. Power and current: The power is between +5% and –10% from the nominal value ot the item.

Chapter 13 and 16. Leakage current and dielectric strength: All are elements with insulation. Applying as stiffness test of 1250 V for 1 minute, between active parts and armor. The leakage current is kept below 0.75 mA/KW between live parts and armor.

Chapter 23. Inner conductors:  If bridges are attached with the device drivers, are considered and met this internal part of the standard.

Chapter 28. Screws and connections: Screws and connections incorporating the element chapter meet this standard.

Test and/or internal controls

Sanara  makes the following tests and/or internal controls:

CERAMIC HEATERS
•    Verification of dimensions (tol. ± 5%)
•    Verification required power and output power (tol. ±10%)
•    Verification of continuity / heaters connected between phases and / or ground
•    Verification of dielectric strength of 1600 Volts (tol. PASS/FAIL)

MICA HEATERS
•    Verification of dimensions (tol. ± 5%)
•    Verification required power and output power (tol. ±10%)
•    Verification of continuity / heaters connected between phases and / or ground
•    Verification of dielectric strength of 1600 Volts (tol. PASS/FAIL)

MEGAWATT HEATERS
•    Verification of dimensions (<100mm => 1.5%, >100mm => 3%)
•    Verification of diameter (from 0.02 mm to 0.08 mm)
•    Verification required power and output power (tol. ±10%)
•    Verification of continuity / heaters connected between phases and / or ground
•    Verification of dielectric strength of 1600 Volts (tol. PASS/FAIL)

CARTRIDGE HEATERS
•    Verification of dimensions (<100mm => 1.5%, >100mm => 3%)
•    Verification of diameter (±0.05%)
•    Verification required power and output power (tol -5% +10%)
•    Verification of continuity / heaters connected between phases and / or ground
•    Verification of dielectric strength of 1600 Volts (tol. PASS/FAIL)